CTIPilot
AI-generated · no human review · verify critical claims against the linked source. how it works →
← Back to the live brief
HIGHCVE-2026-123890 +4exploitedNATOA2vulnerability

CVE-2026-123890, VMware vCenter Server: an unauthenticated authentication bypass in the Directory Service gives an administrator session; GTIG reports the suspected China-nexus actor ARMORY CASTLE exploited it from early September, Broadcom lists no workaround; fixed in 8.0 U3m, 9.0.2.0200 and 9.1.1.0200 (CVSS 3.1 9.8)

vCenter auth bypass exploited since September (GTIG), no workaround: update to 8.0 U3m, 9.0.2.0200 or 9.1.1.0200

Defender actions

  • Update every vCenter Server to 9.1.1.0200, 9.0.2.0200 or 8.0 U3m (VMware Cloud Foundation 5.x to 5.2.5 through KB88287) now as an emergency change, and until it is in, drop inbound TCP 2012 to vCenter from every address that is not an allowlisted management host, as Google's hardening guidance lists, after testing because TCP 2012 is the vCenter SSO control-interface RPC, because GTIG reports exploitation since early September and Broadcom lists no workaround.
  • On every vCenter that was reachable from an internal host before the update, list the SSO and local administrators on vsphere.local that nobody created, review the SSO signing material and ESXi authorized_keys files, because the actor extracted the SAML signing key and created accounts, which updating does not undo.

Analysis

Broadcom's advisory VMSA-2026-0009 of 2026-11-19 fixes CVE-2026-123890, an authentication bypass in the VMware Directory Service of vCenter: an actor with network access can bypass authentication and gain unauthorized access without credentials (CVSS 3.1 9.8) (Broadcom, 2026-11-19). Broadcom lists no workaround, calls the issue an emergency change and does not state exploitation (Broadcom, 2026-11-19). Broadcom credits Mandiant with the report (Broadcom, 2026-11-19), and Google Threat Intelligence Group and Mandiant say ARMORY CASTLE, a suspected PRC-nexus actor, exploited it in early September 2026 with its BONESAW utility, according to forensic evidence (GTIG, 2026-11-19). GTIG describes one intrusion that reached an internal vCenter from a Remote Support appliance compromised through the earlier BeyondTrust zero-day and names no victim sector or country (GTIG, 2026-11-19); BleepingComputer notes that Broadcom has not confirmed the exploitation (BleepingComputer, 2026-11-19).

The flaw is a session-key disclosure over DCE/RPC in the rpc_srp_verifier service on TCP 2012 that yields an authenticated administrator@vsphere.local session; BONESAW then read the Directory Service database, extracted the SAML signing key and created an SSO administrator, SAWSNAKE forged administrator SAML assertions, and the actor switched SSH on through the appliance management API, took the master symmetric key and the PostgreSQL credential file, switched SSH off again, logged in to ESXi hosts, planted an authorized_keys entry and extracted the domain database, registry hives and DNS data from Windows guest virtual disks before copying an archive out over SCP (GTIG, 2026-11-19).

Broadcom's response matrix names the fixes: vCenter 9.1 in 9.1.1.0200, 9.0 in 9.0.2.0200, 8.0 in 8.0 U3m, VMware Cloud Foundation 5.x in 5.2.5 through KB88287 and Telco Cloud through KB463116; vCenter 7.0 has no public fix, and extended-support customers contact Broadcom Support (Broadcom, 2026-11-19). The 8.0 U3m and 9.0.2.0200 updates block later upgrades to VCF 9.1.1 until 9.1.2 (Broadcom, 2026-11-19).

Triage: SSH enablement through the management API alone does not identify this activity; in GTIG's case it followed internal port sweeps from a non-management appliance and was reversed after the credential reads (GTIG, 2026-11-19).

Cited evidence

ARMORY CASTLE exploited this vulnerability in early September 2026 using BONESAW, according to forensic evidence.

Google Threat Intelligence Group / Mandiant 2026-11-19

A malicious actor with network access to vCenter may exploit this issue to bypass authentication and gain unauthorized access to the system.

Broadcom (VMSA-2026-0009) 2026-11-19

The vCenter issue qualifies under ITIL methodologies as an emergency change, requiring prompt action from your organization.

Broadcom (VMSA-2026-0009 Q&A) 2026-11-19

While Broadcom has not confirmed that the flaw was exploited, researchers at Google's Mandiant have documented attacks exploiting CVE-2026-123890.

BleepingComputer 2026-11-19

Sources4

PROVENANCE

AI-generated · no human review · this permalink is the shareable record for the finding · verify operationally critical claims against the linked primary source.