Dutch IGJ: Clinical Diagnostics labs failed NEN 7510 at the time of the July 2025 Nova breach, which reached data of about 941,000 people through an account without MFA in unmonitored legacy systems

Dutch inspectorate finds the hacked cervical-screening lab ran no NEN 7510 audit or periodic risk assessment

Analysis

The Dutch Health and Youth Care Inspectorate (IGJ) concluded on 2026-05-13 that the business units Clinical Diagnostics LCPL BV and NMDL BV in Rijswijk "did not meet the standard either at the time of the hack or during an inspection visit in December 2025" (translated from Dutch): among other gaps, no independent audit of information security had been carried out and processing risks had not been mapped periodically, so the company could not determine which data-security measures it needed (IGJ, 2026-05-13). The Wabvpz requires organisations working with patient data to meet NEN 7510, and IGJ says working to the norm could have reduced the likelihood of an incident like this and limited its consequences (IGJ, 2026-05-13).

Computable reports from the inspection that the company could not establish how the attackers gained access to the compromised user account, which had a 16-character password but no active multi-factor authentication, and that the legacy environments the attackers entered had dropped out of the security operations centre's monitoring through human error, because the SOC wrongly believed them inactive, so anomalous patterns in the logs went unnoticed (Computable, 2026-05-13). Data of about 941,000 people, mostly cervical-cancer screening participants, was viewed or stolen, and Computable reports that the company paid a ransom (Computable, 2026-05-13). The ransomware-as-a-service group Nova had threatened in July 2025 to leak the data, and the screening agency said the lab could not confirm that 941,000 was the full extent (GovInfoSecurity, 2025-09-03).

IGJ asked the company to demonstrate NEN 7510 compliance at short notice; under the Wabvpz it cannot impose punitive measures, while the Dutch data protection authority (AP), which is investigating under the GDPR, can, and the company says an external audit came out positive and certification is expected soon (IGJ, 2026-05-13). IGJ is using the case to call on healthcare providers to work demonstrably to NEN 7510, with a certificate or an independent assessment, and to check actively that the labs and other third parties they use comply (Computable, 2026-05-13).

Cited evidence

The investigation shows that the business units of Clinical Diagnostics involved did not meet the standard either at the time of the hack or during an inspection visit in December 2025. (translated from Dutch)

Working according to this standard could have reduced the likelihood of an information security incident like this and limited the consequences. (translated from Dutch)

Under the Wabvpz the IGJ cannot impose punitive measures. The AP can do so under the GDPR. (translated from Dutch)

IGJ 2026-05-13

However, no multi-factor authentication turned out to be active on the affected account. (translated from Dutch)

Computable 2026-05-13

Updates1

Correction

IGJ asked Clinical Diagnostics to demonstrate NEN 7510 compliance at short notice rather than demanding certification, and the company reports a positive external audit with certification expected soon (IGJ, 2026-05-13). IGJ's release speaks of a data hack and an inspection visit in December 2025; it says working to the norm could have reduced the likelihood of such an incident and limited its consequences, not that the breach scale was their proximate result, and it states no relationship to ISO/IEC 27001 (IGJ, 2026-05-13). The call on all healthcare providers to prove NEN 7510 compliance, including at the labs they use, is reported by Computable from the inspection (Computable, 2026-05-13). Ransomware by Nova and the figure of 941,000 come from press reporting, and the screening agency said the lab could not confirm that this was the full extent (GovInfoSecurity, 2025-09-03).

No cited source compares NEN 7510 with Switzerland's electronic patient record rules or describes the security of Swiss providers. Computable's account of the inspection adds the access vector, a compromised account without multi-factor authentication in legacy environments that had dropped out of SOC monitoring (Computable, 2026-05-13).

Sources3

Revision history

  1. Published 2026-05-14-e05c6e6e
  2. Correction 2026-10-21T1148Z-audit

    IGJ asked Clinical Diagnostics to demonstrate NEN 7510 compliance at short notice rather than demanding certification, the company reports a positive external audit, and IGJ's call on all healthcare providers to prove compliance, including at their labs, comes from Computable's account of the inspection. No source compares NEN 7510 with Switzerland's EPDG or describes Swiss providers, and IGJ says compliance could have reduced the likelihood and limited the consequences of the hack rather than calling the breach scale their proximate result. The Nova attribution and the count of about 941,000 people come from press reporting, and the lab could not confirm the full extent.

    Changed: affected_products body classification entities evidence headline priority sources sourcing_note summary tags techniques title

PROVENANCE

AI-generated · no human review · this permalink is the shareable record for the finding · verify operationally critical claims against the linked primary source.